Class 1 and Class 2
Class 1 is required for legal metrology in environmental noise
Class 2 is sufficient for health & safety
BS61672:2013 is NOT the same as BS60804 which has four Types. This standard is obsolete.
Class 1 BS61672 is NOT the same as Type 1 BS60804
Sound level meter must meet ALL parts of 61672, not just some parts. For example, you CANNOT say “a microphone meets relevant parts of 61672”. It’s all or nothing.
Type approval not required in UK, but no-one in their right mind buys an instrument which has not been type approved elsewhere. Type approval is expensive. There are no short cuts. This affects the end-user price of the instrument. If it’s cheap, there’s a reason.
61672 part 3 covers the tests required for periodic calibration. Make sure your periodic calibration (UKAS or otherwise) covers ALL the tests in that standard, not just some.
It’s IMPOSSIBLE to claim compliance to BS 61672:2013 if all the required information is not provided in the manual for calibration or performance. If this information is not available, the instrument does not meet BS 61672, no ifs no buts. It is not possible to calibrate the instrument otherwise. This includes any correction for specific calibrators.
It’s not enough to say that your instrument meets most of 61672. It must meet all of it.
And it does matter. If any measurement results are presented for compliance with site limits, it is an easy matter for a lawyer to dig up any limitations of the measurement kit in relation to compliance with standards.