SV 104A Personal Noise Dosimeter

The SV 104A Personal Noise Dosimeter measures a worker’s noise exposure throughout their working day. Its compact, body-worn design is suited to assessments where employees move between tasks, machinery and locations with changing noise levels.

Bluetooth connectivity allows measurements to be checked through the Assistant pro smartphone app, while configurable measurement profiles support different occupational noise assessment requirements.

Interested

For more information on SV 104A Personal Noise Dosimeter or to request a quote, contact our team now:

buy now

The SV 104A dosimeter has a very robust MEMS microphone that has a lifetime warranty.  All vibrations that affect noise measurement results are detected by an inbuilt tri-axial vibration accelerometer and are marked in the results time history, so they can be easily excluded from dose calculations. Additionally, the accelerometer detects if dosimeter is not used by the worker and marks this information in time history.

We have designed the SV  104A to make noise dosimetry measurements easier. Firstly, the voice comment feature replaces necessity of identifying the dosimeter with a different type of stickers. Secondly, a single large measurement range of 53 dB to 141 dB enables measurement in all kinds of working environment. But mostly, the auto-calibration is what makes the SV  104A easy in use. Once the SV 104A detects a calibration signal, it calibrates automatically saving the calibration data together with the measurement file, before and after measurement.

The list of distinguishing features of SV  104A includes a colour OLED display that can be easily read even in a full daylight or in the dark. The user interface is very friendly to use which makes setting up and using the instrument easier than ever. The user may choose from multiple setup files that can be configured through the included Supervisor software. All measurement data are stored in the integral 8 GB memory which provides a vast amount of storage.

SV104A Technical Specifications

StandardsIEC 61252; ANSI S1.25-1991; Class 2: IEC 61672-1:2013
Weighting filtersA, C and Z
Time constantsSlow, Fast, Impulse
Exchange rates2, 3, 4, 5, 6
Measurement resultsLavg/Leq, SPL, Max, Min, SEL, SEL8, PSEL, LEPd, Dose (%), TWA, E, E_8h, Peak, Run Time, Upper Limit, Time (ULT), L(C-A), Projected Dose (D_8h)
Measurement profiles3
MicrophoneClass 2 microphone, 1/2″ MEMS type
Measurement range53 dBA RMS ÷ 141 dBA Peak
Frequency range20 Hz ÷ 10 kHz
Dynamic range98 dB
Data loggingSummary results for the measurement time
Time-history logging of Leq/Max/Min/Peak with 1s logger step
Voice commentsAudio records on demand, created before or after measurement, added to measurement file
Audio recordingAudio events recording, trigger and continuous mode, 12 or 24 kHz sampling rate, wav format (option)
1/1 octaveReal-time analysis in octave band filters, Class 1, IEC 61260
9 filters with centre frequencies from 31.5 Hz to 8 kHz (option)
1/3 octaveReal-time analysis in 1/3 octave band filters,Class 1 IEC 61260; 28 filters with centre frequencies from 20 Hz to 10 kHz (option)

Basic data

Display128 x 64 pixels OLED
Memory8 GB
InterfacesUSB 2.0 client, electrical contacts (new-type docking station compatible)
Long-range Bluetooth®, 4.0 Smart
Keyboard3 push buttons
Power supplyLi-Ion rechargeable cells: operation time > 48 hours1
USB interface 500 mA HUB
Environmental conditionsTemperature from -10 oC to 50 oC
Humidity up to 95 % RH, non-condensed
Dimensions 88 x 49.5 x 19.2 mm
Weight121 grams with batteries

 1depends on instrument settings

*Continuous product development and innovation are the policy of our company. Therefore, we reserve the right to change the specifications without prior notice.

Accessories available for the SV 104A Personal Noise Dosimeter:

SA 122A

Windscreens for SV 104 / SV 104A dosimeter 3 pcs pack thread fixing

SA 122A

SA 150, SA 151 I, SA 152

SA 150, SA 151 I, SA 152

SA 73 Case

Carrying case for 5 x SV104IS/SV 104 dosimeters and accessories only, waterproof, no space for SA104-5

SA 73

SC 156

Micro USB cable

SC 156

SA 147

Carrying case for 1 x SV 104 dosimeter and accessories (waterproof)

SA 147

ST 104CIS

Microphone for SV 104, SV 104A, SV 104BIS dosimeters originally delivered with ST 104CIS microphones

ST 104CIS

For more details or to order accessories for the SV 104A Personal Noise Dosimeter, get in touch with our team.

Personal Noise Monitoring Across the Working Day

A worker’s noise exposure can vary considerably between tasks. The SV 104A records exposure over time, helping assessors understand the contribution of different activities to the overall result.

Typical applications include:

  • Manufacturing and production environments
  • Construction and maintenance work
  • Warehousing and materials handling
  • Engineering workshops and machinery operation

Personal noise monitoring is particularly useful when a worker’s movements make it difficult to capture representative exposure using individual spot measurements.

SV 104A Personal noise dosimeter

Review Events and Understand Exposure

The SV 104A stores a time history of noise measurements, allowing assessors to review how levels changed during the monitoring period. Comparing this record with a log of tasks and working conditions helps identify activities that warrant further investigation.

The integrated vibration sensor marks shocks and movement that may affect the results. These markers help assessors review potential interference before deciding whether any data should be excluded.

Bluetooth communication also allows measurement progress to be checked without needing to approach the wearer each time.

104A Personal noise dosimeter on side

Plan Your Workplace Noise Assessment

Useful results depend on representative monitoring periods, appropriate instrument settings and clear records of the work undertaken. Calibration checks before and after monitoring help document instrument performance. All configuration takes place through the Supervisor software.

Svantek UK can discuss the SV 104A, suitable accessories and software for your assessment requirements.

Contact our team for advice on selecting personal noise monitoring equipment, or find out about our calibration services.

104a Personal noise dosimeter occupational noise

Health & Safety

From the Noise at Work Act to the Physical Agents Directive (Vibration) we have instrumentation to ensure you stay within the law.