Outdoor Noise Monitoring

Short and long-term noise monitors for construction, environmental and industrial noise measurement.

At AcSoft we carry a range of complete noise & vibration measurement systems such as sound level meters, measurement microphones, vibration metres, and digital sound level meters which are ideal for sound level and frequency analysis. We provide a wide range of systems from well-known manufacturers including Svantek, Sinus and more. We also stock in-situ absorption, Scan & Listen and Scan & Paint from Microflown along with acoustic cameras from gfai tech.

  • Outdoor noise monitoring involves measuring environmental sound levels using specialised equipment such as sound level meters and microphones.
  • It is essential for compliance with environmental noise regulations, planning assessments, and long-term monitoring projects.
  • AcSoft offers a wide range of outdoor noise and vibration monitoring systems from leading manufacturers including Svantek, Sinus, Microflown, and gfai tech.

Outdoor Noise Monitoring

Understanding and managing environmental sound is essential across a wide range of sectors. AcSoft offers an extensive selection of outdoor noise monitoring systems designed to deliver precise, reliable data even in the most challenging conditions.

What is outdoor noise monitoring?

Outdoor noise monitoring involves the continuous or periodic measurement of sound levels in the outdoor environment. This typically includes construction sites, urban developments, transport infrastructure, and industrial areas. An outdoor noise monitoring system captures real-time acoustic data to assess environmental impact, ensure regulatory compliance, and support planning decisions.

Who uses outdoor noise monitoring equipment?

These systems are widely used by environmental consultants, local authorities, construction firms, and event organisers. Transport planners and infrastructure developers also depend on accurate outdoor noise monitoring to mitigate the effects of sound pollution on nearby communities. From short-term assessments to long-term strategic monitoring, professionals across many different industries rely on trusted acoustic measurement solutions.

Outdoor vs Indoor Noise Monitoring

Whilst both systems measure sound levels, outdoor monitoring equipment must be robust enough to operate in unpredictable weather and fluctuating temperatures. Indoor devices are often smaller and more sensitive to subtle acoustic changes within controlled environments, such as laboratories or workplaces. In contrast, outdoor equipment prioritises durability, remote access, and secure enclosures to protect hardware from the elements.

Are Outdoor Noise Monitors Weatherproof?

Yes, outdoor noise monitoring systems are designed to be able to withstand exposure to rain, wind, humidity, and variations in temperatures. Many include weatherproof microphones, windscreens, and protective cases rated to IP standards. AcSoft supplies systems that offer long-term reliability outdoors, with the option of integrating solar panels or battery power for remote operation.

Is Outdoor Noise Monitoring Mandatory On UK Construction Sites?

In many circumstances, yes. Construction projects that pose a risk of noise disruption often require a Section 61 consent under the Control of Pollution Act 1974. This sets clear limits on permissible noise levels. Continuous outdoor noise monitoring not only demonstrates compliance but also supports stakeholder engagement and community transparency.

Can Your Systems Support Section 61 Compliance?

Absolutely. AcSoft provides outdoor noise monitoring equipment that is fully compatible with Section 61 reporting requirements. Our systems can log, store and transmit data in real-time, enabling you to respond swiftly to potential breaches. We also offer calibration services to ensure your instruments remain accurate and legally defensible throughout the project lifecycle.

Expert Support From AcSoft

At AcSoft, we go beyond supplying equipment. Our team offers industry-specific guidance, technical support, and calibration services to maintain system accuracy. Whether you’re managing a complex infrastructure project or need a straightforward monitoring solution, we are here to assist you. For bespoke advice, or to discuss your next project, contact us today.

Knowledge Hub

Scan&Paint 2D vs Scan&Paint 3D

April 28, 2026

Acoustic troubleshooting and sound source localisation provide insights that traditional measurement techniques can struggle to deliver. This is why tools like Scan&Paint 2D and Scan&Paint 3D are becoming so popular in the engineering field. These tools allow engineers to transform acoustic data into clear visual sound maps, making it easier…

read article

A Deep Dive into Scan&Paint 2D

April 15, 2026

NVH Engineers face acoustic challenges every day. This could be troubleshooting noise, optimising products or improving soundproofing. Identifying the true source of unwanted sound is rarely straightforward. Traditional acoustic measurements can tell you how loud something is, but they often struggle to clearly show where the noise is coming from.…

read article

A Deep Dive Into the SV 307A

April 13, 2026

Managing environmental noise is a key part of modern construction, infrastructure projects, and urban development. But how do you measure it reliably, over long periods, without constant site visits? Well, with a permanent noise monitoring station. Introducing the SV 307A, giving consultants, construction companies and environmental professionals a dependable way…

read article

Why Turnaround Time of Calibration Services Matters

April 1, 2026

At AcSoft we understand the frustrations of waiting weeks and paying unnecessary fees for the calibration of your systems. That’s why we’ve refined our calibration process to prioritise speed (turnaround time), cost and knowledge. Our service is built to ensure your instruments are back in action without delay. Why Turnaround…

read article