Home Products Building Acoustics & STiPA The Building Acoustics Kit

The Building Acoustics Kit

The Building Acoustics Kit brings together the instruments and software needed for airborne and impact sound insulation testing. Built around the SV 971A Class 1 Sound Level Meter, it combines a sound source, tapping machine, acoustic calibrator and Building Acoustics PRO App to support on-site measurement and reporting.

The package includes the measurement licences listed below and UKAS calibration, providing a coordinated setup for building acoustics professionals.

Interested

For more information on The Building Acoustics Kit or to request a quote, contact our team now:

Our Building Acoustics Kit is made up of:

  • SV 971A Class 1 Sound Level Meter
  • Building Acoustics PRO App offers direct integration into the SITMA portal 
  • EOS 2.0 Tapping Machine
  • SL 203AC Dodecahedral Sound Source
  • SV 33B Class 1 Acoustic Calibrator
  • Reverberation Time Analysis (RT60) License
  • Licence of 1/1 & 1/3 Octave Analysis
  • Licence of Audio Events Recording
  • SA 72 carry case for sound level meter
  • UKAS calibration included

 

Example Data From Svantek BA Assistant App – how we do our calculations!

 

Equipment for Airborne and Impact Sound Insulation Testing

The kit supports two key aspects of building sound insulation assessment:

  • Airborne sound insulation: the SL 203AC Dodecahedral Sound Source generates sound in the source room, while the sound level meter records measurements used to assess transmission into the receiving room.
  • Impact sound insulation: the EOS 2.0 Tapping Machine provides a repeatable impact source for assessing sound transmitted through floors.

The included reverberation time and octave analysis licences support the measurements needed for sound insulation calculations. The SV 971A Class 1 Sound Level Meter provides the measurement platform, with the SV 33B Acoustic Calibrator available for field calibration checks.

Dodec 203 AC

Guided Measurements and Clear Reporting

The Building Acoustics PRO App guides users through sound insulation measurement procedures in accordance with ISO 16283.

Measurements are organised into projects containing source-room and receiving-room data for different sound source positions. Users can review results as tables and plots, add photographs and voice comments, and generate Excel reports directly from the app.

Projects can also be downloaded to SvanPC++ software for further post-processing.

Discuss Your Building Acoustics Testing Requirements

Choosing a kit involves more than selecting a sound level meter. The required test procedure, sound sources, software licences and calibration arrangements all need to suit the work being undertaken.

Our team can discuss the package contents and help you establish whether this setup meets your requirements. Explore our wider building acoustics equipment or contact AcSoft for advice and a quotation.