Airly Aura

Airly is a MCERTS certified device that measures the air quality in your immediate surroundings. Accurate, certified and verified in various environmental conditions are the best source of real-time air pollution measurements.

Interested

For more information on Airly Aura or to request a quote, contact our team now:

Compatible with SvanNET

The Airly Aura can be used with SvanNET for remote communication and automatic monitoring services.

try our live demo

A industry leading air quality sensor that measures PM1, PM2.5 and PM10. The sensor includes data access via the Airly Data Platform, with reliable GSM data transfer ensuring smooth integration and monitoring.

Details:

  • Easy to assemble
  • Waterproof
  • LED diode presenting measurements in CAQI or AQI scale
  • Temperature
  • Humidity
  • Air pressure

A single Airly device can measure two chemical compounds by the electrochemical method. Readings are taken from two gas cells installed in the measurement module of the sensor. Each sensor is equipped with a light diode that changes to present the current air quality using colour signals consistent with the CAQI or AQI scale.

Sensors can track all the key pollution markers like particulate matter (PM1, PM2.5, PM10), NO2, O3, SO2, H2S, NO, and CO gases. They also provide reliable data about key weather parameters such as temperature, humidity, air pressure, and wind from sensor locations.

Installation of the sensor is effortless. All it needs to work correctly is to be plugged into a regular power socket and hung on a height minimum of 1,5 m above the ground and not higher than 8 m. After 48h, calibrated measurements are visible on the Airly Data Platform, Airly Map and Airly Mobile App.

Why Airly?

  • Small and ready to install
  • Quality proven in various weather conditions
  • Secure and efficient data transmission using GSM protocol
  • Easily accessible via the Airly Data Platform, Airly Map or Mobile App

See for yourself how quick and easy the Airly installation is with this installation tutorial.

If you’re planning to power instrumentation with an external battery, use our battery runtime calculator.

Constant Working Conditions

Temperature-40oC – +80oC
Humidity0 – 100%
Pressure700 – 1 200 hPa

Measurements

PM1, PM2.5, PM10, temperature (°C), pressure (hPa), humidity (%)
types: NO 2 +O3, SO2 +CO, NO2 +NO

 

RangeAccuracy
Temperature-40oC – +80oC± 0,1oC
Pressure700 – 1 200 hPa± 1 hPa
Humidity0 – 100%± 1%

 

Measurement Frequency

Sampling Interval1-2 sec
Averaging Interval5 min
Sending interval15 min
(3 samples with a 5-minute average

Enclosure Parameters and Weight

Case materialStainless steel
Dimensions74 x 112* x 83,5 mm
Device weight490g

SHARE THIS