Home Products Building Acoustics & STiPA SVAN 979 Sound and Vibration Analyser

SVAN 979 Sound and Vibration Analyser

The SVAN 979 is a class 1 type approved sound level meter and analyser with the superior technical specifications. Its measuring range starts from as low as 12 dBA!

Interested

For more information on SVAN 979 Sound and Vibration Analyser or to request a quote, contact our team now:

Overview
Specification
Download

SVAN  979 is a device combining all necessary measurement functionalities in one hand-held tool. The instrument is dedicated for acoustic engineering applications such as sound insulation measurements, precise frequency or signal tonality analysis. In standard, this sophisticated tool has been equipped with frequency analysis in 1/1 & 1/3 octave bands, FFT analysis and audio recording for noise source recognition.

Basic kit also includes building acoustic pack: RT 60 measurement and signal generator functions.

New generation sound level meters

The new SV 973 class 2 sound level meter, and the SV 971A class 1 sound level meter are two new generation models that comply with IEC 61672. They have a small size and weight as well as improved application compatibility via mobile apps, which is their main feature.

SVAN 979 Sound Level Meter Specification

StandardsClass 1: IEC 61672-1:2013 (PTB approval 21.21/13.06)
Number of Profiles3
Weighting FiltersA, B, C, Z, G
Time constantsSlow, Fast, Impulse
RMS DetectorDigital True RMS detector with Peak detection, resolution 0.1 dB
MicrophoneGRAS 40AE, 50 mV/Pa, prepolarised 1/2” condenser microphone
PreamplifierSV 17 IEPE type / 200V external polaristation compatible
Linear Operating Range22 dBA RMS ÷ 140 dBA Peak (in accordance to IEC 61672)
Total Dynamic Measurement Range12 dBA RMS ÷ 140 dBA Peak (typical from noise floor to the maximum level)
Internal Noise Levelless than 12 dBA RMS
Dynamic Range>110 dB
Frequency Range3.15 Hz ÷ 20 kHz with GRAS 40AE microphone
Meter Mode ResultsSPL, Leq, SEL, Lden, LEPd, Overload time, Ltm3, Ltm5, LMax, LMin, LPeak,
Simultaneous measurement in three profiles with independent filters and detectors
StatisticsLn (L1-L99), complete histogram in meter mode, averaging: linear of with detector (exponential)

Ln (L1-L99) statistics in 1/1 or 1/3 octaves (if option is active)

Data Loggerlogging of summary results with step from 10 s (auto-save function)

logging of time history with step from 2 ms

Audio Recording (option)Audio events recording during measurement, trigger or continuous mode, 12 / 24 / 48 kHz sampling rate, 16 or 24 bit, wav format
Wave Recording (option)Time domain signal recording during measurement 12 / 24 / 48 kHz sampling rate, 16 or 24 bit, wav format

Sound Analyser

1/1 Octave Analysis (included)Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 31.5 Hz to 16 kHz (audio band), selectable weighting filter, selectable detector or

Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 1 Hz to 16 kHz  (full band), selectable weighting filter, detector linear

1/3 Octave Analysis (inlcuded)Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 20 Hz to 20 kHz (audio band), selectable weighting filter and selectable detector or

Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 0.8 Hz to 20 kHz  (full band), selectable weighting filter, linear detector

1/6 Octave Analysis (option)Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 20 Hz to 21.4 kHz (audio band), selectable weighting filter and selectable detector or

Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 0.73 Hz to 21.4 kHz  (full band), selectable weighting filter, linear detector

1/12 Octave Analysis (option)Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 20.3 Hz to 22 kHz (audio band), selectable weighting filter and selectable detector or

Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 0.71 Hz to 22 kHz  (full band), selectable weighting filter, linear detector

 FFT Analysis (included)400 or 800 or 1600 lines in selectable band from 78 Hz to 20 kHz with selectable weighting filter, selectable averaging: linear or exponential, and selectable window
Tonality (option)Pure tone detection, FFT -based,  according to Joint Nordic Method and ISO 1996
RT 60 (included)Reverberation time analysis in 1/3 octaves, selectable method: decay or impulse
Signal Generator (included)Sine, White noise, Pink noise
RPM (option)Rotation measurement option without Laser Tachometer (option), measurement of RPM, RPS, RMAX, RMIN
User filters (option)Selectable real time filter: low pass, high pass and band pass filters option

Vibration Level Meter

StandardsISO 10816-1
Number of Profiles3
Weighting FiltersAcceleration: HP1, HP3, HP10, Wh; Velocity: Vel1, Vel3, Vel10, Displacement: Dil1, Dil3, Dil10

Machine filter: VelMF (ISO 10816-1)

RMS DetectorDigital True RMS detector with Peak detection, resolution 0.1 dB
Time constants: from 100 ms to 10 s
Meter mode resultsRMS, MAX, Peak, Peak-Peak, Overload time, MTVV,
Accelerometer (option)SV 80 IEPE, single axis, sensitivity 10 mV/(ms-2) ~ 100 mV/g
Measurement Range0.01 msRMS ÷ 500 ms-2 Peak (with SV 80)
Frequency Range1 Hz ÷ 5 kHz (with SV 80 and HP or HP1 filter)

Vibration Analyser

1/1 Octave Analysis (included)Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 1 Hz to 16 kHz  (full band), HP weighting filter, detector linear
1/3 Octave Analysis (inlcuded)Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 0.8 Hz to 20 kHz  (full band), HP weighting filter, detector linear
1/6 Octave Analysis (option)Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 0.73 Hz to 21.4 kHz  (full band), HP weighting filter, detector linear
1/12 Octave Analysis (option)Real-time analysis meeting Class 1 requirements of IEC 61260, centre frequencies from 0.71 Hz to 22 kHz  (full band), HP weighting filter, detector linear
 FFT Analysis (included)400 or 800 or 1600 lines in selectable band from 78 Hz to 20 kHz with selectable weighting filter, selectable averaging: linear or exponential, and selectable window
RPM (option)Rotation measurement option without Laser Tachometer (option), measurement of RPM, RPS, RMAX, RMIN
User filters (option)Selectable real time filter: low pass, high pass and band pass filters option

General information

InputLEMO 7-pin: Direct AC, Direct AC with 200 V polarisation, Direct DC or IEPE type with TEDS
Self-vibration MonitoringBuilt-in shock detection
Dynamic Range115 dB
Frequency Range0.5 Hz ÷ 22.4 kHz, sampling rate 48 kHz

0.5 Hz ÷ 40 kHz, sampling rate 96 kHz (ultrasound version)

Memory32 MB non-volatile flash type, micro SD card 8 GB (removable & upgradeable)
DisplayColour 320 x 240 pixels, OLED type
Keyboard9 push buttons
Communication InterfacesUSB 1.1 client
Bluetooth®
RS 232 (with SV 55 option)
GPS time synchronisation and positioning (option)
External I/O – AC output (1 V Peak) or Digital Input/Output (Trigger – Pulse)
 Power supplyFour AA rechargeable NiMH batteries (included)
USB interface 500 mA HUB
External power supply 6 V/500 mA DC ÷ 15 V/250 mA DC
SA 17A external battery pack (option)
Environmental ConditionsTemperature from -10 oC to 50 oC
Humidity up to 90% RH, non-condensed
Dimensions305 mm x 79 x 39 mm (including microphone and preamplifier)
Weight Approx. 0.6 kg with batteries

*Continuous product development and innovation are the policy of our company. Therefore, we reserve the right to change the specifications without prior notice.

SHARE THIS

Applications

SVAN 979

Dedicated for acoustic engineering applications such as sound insulation measurements or signal tonality analysis

Related Products